1 1/2 Storey Range Standard Kit Specification |
---|
GROUND FLOOR |
Concrete Slab: By others, unless full build by ACJ Group. |
KPDC: DPC (to BS 6515). |
Wallplate: To suit one of ACJ wall systems. |
Fixings: Hilti hammer fixings, typically at 900mm centers. (Confirmed by engineering) |
EXTERNAL WALL PANELS |
We offer a variety of wall systems with U-Values ranging from 0.14 W/m2K – 0.09 W/m2K and our Therm-u-wall system achieving a U-Value of 0.08W/m2K and within each system, the insulation varies. Have a look at our wall systems and choose which system you would like to be priced for. |
Studs: To suit one of ACJ wall systems. |
Headbinders: To suit one of ACJ wall systems. |
Lintols: As per engineering requirements. |
Breather Paper: Protect TF200 reflective. |
Fire Stops: 38 x 50m w/w, supplied at stock lengths. |
INTERNAL LOAD BEARING PARTITIONS |
Top & Bottom Rails: 45 x 95mm / 45 x 145mm C16 timbers. |
Studs: 45 x 95mm / 45 x 145mm C16 timbers. |
Headbinders: 45 x 95mm / 45 x 145mm C16 timbers. |
Lintols: 45×220 C24 2ply / 3ply. |
Dwangs: 1 centred row of 45 x 95mm / 45 x 145mm C16 timbers. |
RACKING PARTITIONS (As per engineering requirements) |
Top & Bottom Rails: 45 x 95mm / 45 x 145mm C16 timbers. |
Studs: 45 x 95mm / 45 x 145mm C16 timbers. |
Headbinders: 45 x 95mm / 45 x 145mm C16 timbers. |
Lintols: 45×220 C24 2ply / 3ply. |
Sheathing: 9mm OSB3, one side. |
INTERNAL NON-LOADBEARING PARTITIONS |
Top & Bottom Rails: 45 x 70mm C16 timbers. |
Studs: 45 x 70mm C16 timbers. |
Dwangs: 1 centred row of 45 x 95mm / 45 x 145mm C16 timbers. |
ROOF TRUSSES |
Mitek or Gangnail roof trusses typically at 600mm centers in accordance with BS EN 1995-1-1:2004. |
Gable ladders: 35x97mm, 20mm barge boards & 9mm ply soffit supplied loose. |
Wind bracing: 22 x 100mm w/w, in accordance with BS5268-3:2006 |
Sarking: 9mm OSB Sheathing |
Roofing Membrane: Daltex RoofTX Optima. |
Valley boards: 9 x 200mm OSB. |
Tilting fillets: 9 x 200mm OSB. |
Counter battens: 12 x 50 w/w, supplied at stock lengths. |
Tiling Battens: 25 x 50mm w/w, supplied at stock lengths. |
Fascia boards: 20mm redwood treated. |
Soffits: 9mm WBP Ply. |
Soffit framing: 38 x 50m w/w, supplied at stock lengths. |
All necessary fixings for roof truss erection included with roof supply. |
SUNDRIES |
Ceiling hatch qty 1 |
Cylinder stool qty 1 |
Meter board qty1 |
WINDOWS |
(Average U Value 1.4W/m2K) High-performance U.P.V.c top hung casement windows. GREY to the outside and white to the inside. Fitted with 28mm low-e, argon filled double glazed units. Toughened glass where required, and satin chrome ironmongery. |
EXTERNAL DOORS |
(Average U Value 1.4W/m2K) High Performance external door, GREY external and white internal. Fitted with a 3-point locking, glass top and solid panel to the bottom. Fitted with satin chrome ironmongery. |
INTERNAL DOORSETS |
Canterbury 4 panel woodgrain white primed door. Pre-hung in redwood frames with stops fitted Latches and locks pre-fitted with satin chrome furniture. |
FINISHINGS |
Skirting’s: 15 x 95mm white primed MDF. |
Facings: 15 x 70mm white primed MDF. |
Skirting Blocks: white primed MDF. |
Window Cills: 20mm white primed MDF. |
Apron plates: 15mm white primed MDF. |
STAIRS |
Stringers: Red pine. |
Handrail: Red pine. |
Newels: Turned red pine. |
Spindles: Turned red pine. |
Treads: 22mm MDF |
Risers: 9mm MDF |
SHELVING |
Wardrobes: 18mm MDF shelving |
Storage cupboards: 18mm MDF shelving |
Cloaks: 18mm MDF shelving |
Linen: 18mm MDF shelving |
Rails & Fixings: Satin chrome hanging rails and brackets. |
PLASTERBOARD |
External Walls: 12.5mm TE Duplex |
Internal Walls: 12.5mm TE Duplex |
Bathrooms: 12.5mm TE Moisture Resistant |
Ceilings: 12.5mm TE Duplex |
INSULATION |
We offer a variety of wall systems with U-Values ranging from 0.14 W/m2K - 0.09 W/m2K and our Therm-u-wall system achieving a U-Value of 0.08W/m2K and within each system, the insulation varies. Have a look at our wall systems and choose which system you would like to be priced for. |
IRONMONGERY |
All structural ironmongery will be supplied to enable kit erection only. |
TERMS |
---|
All house rendering images are for visual aid only and may not truly represent the finished look of the build depending all products and materials used. Always be sure to thoroughly discuss all aspects of your building project, ensuring all colours and finishes are to your understanding. Floor plan dimensions and interior room sizes are accurate, but may have been rounded for brochure plans. |
Due to occasional updating of building regulations, material costs, availability and ACJ Group continuous product improvement, specifications are subject to change without prior notification. |
ACJ Wall System details are based on timber frame walls designed by ACJ Group and incorporating earth wool products and a generic polyurethane foam. |
All timber frame kit home prices exclude delivery costs and will be advised and priced upon confirmation of timber frame kit delivery address. |