Standard Roof Truss
Truss Centres (mm): 600
Timber Thickness (mm): 35
Timber Thickness (mm): 35
Standard Roof Truss |
---|
General Load Settings: Tile Load: 0.785 kN/m² Snow Load: 0.524 kN/m² Ceiling Dead Load: 0.250 kN/m² Ceiling Live Load 0.250 kN/m² Tank Load 0.450 kN Max Tile Batten Centres: 360 mm |
General Truss Information: Truss Centres (mm): 600 Timber Thickness (mm): 35 |
Timber Size Information: Member Size Grade TC 1-4,4-7 – 97 TR26 BC 6-10 – 72 TR26 BC 10-2 – 72 TR26 WB 3-8,5-9 – 72 TR26 WB 4-8,4-9 – 72 TR26 |
All truss images are for visual aid only and may not truly represent the roof truss supplied or designed by your chosen supplier. Always be sure to thoroughly discuss all aspects of your roof design with the supplier ensuring all materials, loadings and specifications are to your understanding. |