Wall System Series 1.1 | A Series 1.1 | B Series 1.1 | C Series 1.1 | D Series 1.1 | E Series 1.1 | F Series 1.1 |
|
---|---|---|---|---|---|---|---|
Wall system structural thickness | 145mm | 145mm | 195mm | 195mm | 220mm | 220mm | |
U Value W/m2K (Block & Render Finish by others) | U-value 0.17 W/m2K | U-value 0.14 W/m2K | U-value 0.14 W/m2K | U-value 0.12 W/m2K | U-value 0.11 W/m2K | U-value 0.10 W/m2K |
|
Timber Fraction - Structure vs Insulation | Timber 13.60% | Timber 13.60% | Timber 13.60% | Timber 13.60% | Timber 10.72% | Timber 10.72% |
|
(Based on a 2.4m wide by 2.4m high by structural wall thickness depth ) | Insulation 86.40% | Insulation 86.40% | Insulation 86.40% | Insulation 86.40% | Insulation 89.28% | Insulation 89.28% |
|
Timber cold/thermal bridge transference (Based on a 2.4m wide by 2.4m high panel) | Bridging 12.75% | Bridging 12.75% | Bridging 12.75% | Bridging 12.75% | Bridging 3.75% | Bridging 3.75% |
|
Breather Membrane | Reflective | Reflective | Reflective | Reflective | Reflective | Reflective | |
Panel Sheathing | OSB 3 | OSB 3 | OSB 3 | OSB 3 | OSB 3 | OSB 3 | |
Timber Frame Structure | 45x145mm C16 Timber | 45x145mm C16 Timber | 45x195mm C16 Timber | 45x195mm C16 Timber | C16 + C24 Dual Timber | C16 + C24 Dual Timber |
|
Insulation Within Structure | 035-Wool to suit thickness | 035-Wool to suit thickness | 035-Wool to suit thickness | 035-Wool to suit thickness | 035-Wool + 50mm PUR to suit thickness | 035-Wool + 50mm PUR to suit thickness |
|
Vapour control layer | Reflective | Reflective | Reflective | Reflective | Reflective | Reflective | |
Internal Insulated Board | 25mm PUR | 50mm PUR | 25mm PUR | 50mm PUR | 25mm PUR | 50mm PUR | |
Service Void / Battens | 38mm | 38mm | 38mm | 38mm | 38mm | 38mm | |
Plasterboard | 12.5mm TE Plain | 12.5mm TE Plain | 12.5mm TE Plain | 12.5mm TE Plain | 12.5mm TE Plain | 12.5mm TE Plain |
Wall System Series 1.1 | G Series 1.1 | H Series 1.1 | I Series 1.1 | J Series 1.1 | K Series 1.1 | L Series 1.1 | |
---|---|---|---|---|---|---|---|
Wall system structural thickness | 235mm | 235mm | 300mm | 300mm | 300mm | 300mm | |
U Value W/m2K (Block & Render Finish by others) | U-value 0.11 W/m2K | U-value 0.10 W/m2K | U-value 0.10 W/m2K | U-value 0.09 W/m2K | U-value 0.09 W/m2K | U-value 0.08 W/m2K |
|
Timber Fraction - Structure vs Insulation | Timber 12.68% | Timber 12.68% | Timber 12.68% | Timber 12.68% | Timber 10.95% | Timber 10.95% |
|
(Based on a 2.4m wide by 2.4m high by structural wall thickness depth ) | Insulation 87.32% | Insulation 87.32% | Insulation 87.32% | Insulation 87.32% | Insulation 89.05% | Insulation 89.05% |
|
Timber cold/thermal bridge transference (Based on a 2.4m wide by 2.4m high panel) | Bridging 5.55% | Bridging 5.55% | Bridging 5.55% | Bridging 5.55% | Bridging 3.75% | Bridging 3.75% |
|
Breather Membrane | Reflective | Reflective | Reflective | Reflective | Reflective | Reflective | |
Panel Sheathing | OSB 3 | OSB 3 | OSB 3 | OSB 3 | OSB 3 | OSB 3 | |
Timber Frame Structure | 47x235mm JJI Joists | 47x235mm JJI Joists | 47x300mm JJI Joists | 47x300mm JJI Joists | C16 + GL28 Dual Timber | C16 + GL28 Dual Timber |
|
Insulation Within Structure | 035-Wool to suit thickness | 035-Wool to suit thickness | 035-Wool to suit thickness | 035-Wool to suit thickness | 035-Wool + 60mm PUR to suit thickness | 035-Wool + 60mm PUR to suit thickness |
|
Vapour control layer | Reflective | Reflective | Reflective | Reflective | Reflective | Reflective | |
Internal Insulated Board | 25mm PUR | 50mm PUR | 25mm PUR | 50mm PUR | 25mm PUR | 50mm PUR | |
Service Void / Battens | 38mm | 38mm | 38mm | 38mm | 38mm | 38mm | |
Plasterboard | 12.5mm TE Plain | 12.5mm TE Plain | 12.5mm TE Plain | 12.5mm TE Plain | 12.5mm TE Plain | 12.5mm TE Plain |
TERMS |
---|
All house rendering images are for visual aid only and may not truly represent the finished look of the build depending all products and materials used. Always be sure to thoroughly discuss all aspects of your building project, ensuring all colours and finishes are to your understanding. Floor plan dimensions and interior room sizes are accurate, but may have been rounded for brochure plans. |
Due to occasional updating of building regulations, material costs, availability and ACJ Group continuous product improvement, specifications are subject to change without prior notification. |
ACJ Wall System details are based on timber frame walls designed by ACJ Group and incorporating earth wool products and a generic polyurethane foam. |
All timber frame kit home prices exclude delivery costs and will be advised and priced upon confirmation of timber frame kit delivery address. |